Products

Inert Gas Oven INL Series

Hot-air circulation type ovens performing heat treatments in the environments using N2 atmospheres at 20 ppm or lower O2 concentrations.
They achieve ceramic part debinding (defatting), annealing and other effective heat treatments.
Inert Gas Oven INL Series

Maximum temperature
350°C

Feature

  • 20 ppm or lower residual O2 concentrations are achieved. Heat treatments at low O2 concentrations are available.
  • 2 purge running flowmeters are used.
  • A simple, easy-to-operate programmer is used for easy and secure operations.
  • A PV, SV and programmer status display is used. Operation status can be monitored at one view.
  • Optimal for researches and development
* Please contact us about safety feature for ceramic degreasing.
Applications Research and Development
Option Shelves (with shelf plates), Temperature Recorder

The inert gas ovens can perform heat treatments in a N2 atmosphere at up to 350°C of working temperatures and achieve 20 ppm or lower residual O2 concentrations. The side-flow hot-air circulation system achieves uniform furnace internal temperature environment. In addition to researches and development, this series of ovens is sufficiently cost-effective for small-volume production. Programmable operations are available and touch panels are used for the operation panels.

Inquiry about products
  • In addition to standard models, special specifications are available.
    If you are interested, access here.
20 ppm or lower residual O2 concentrations
INL series specifications
Method Convection (Side-flow)
Max. operation Temperature(*1) 350°C
Normal operation Temperature(*1) RT+60~350°C
Temperature distribution (Reference)(*2) ±5°C(at 350°C)
Heat up time (Reference)(*1) Within 60 minutes (RT+60~350°C)
Oxygen concentration (Reference) Less than 20 ppm
Withstand load (Uniformly-distributed load) 15kg/1 sheet
Chamber pressure meter 0~2kPa
Thermocouple K
Control System Temperature Programmer
Exhaust port 1B · ball value
Safety feature Electric leak breaker,
Thermocouple disconnection,
Over-heat protection,
Control circuit breaker
Standard accessory Shelves (with shelf plates),
Temperature Recorder
(*1) Temperature at the control point within the heating chamber.
(*2) Valid dimension is two-thirds inside dimension.
☆ Thermocouples are consumable items.
Type INL-45N1 INL-60N1
Oxygen concentration (Reference) Within 60 minutes
(N2·50 L/min introduce)
Within 60 minutes
(N2·90 L/min introduce)
Heater Power 6.9kW(at 200V) 8.4kW(at 200V)
Outer dimension (mm) 1200(W)×1030(H)×800(D) 1350(W)×1180(H)×950(D)
Inside dimension (mm) 450(W)×450(H)×450(D) 600(W)×600(H)×600(D)
Equipment weight approx. 250kg approx. 350kg
Breaker capacity AC200V 30A
3ø 50/60Hz
AC200V 40A
3ø 50/60Hz